Product

4/10 and 6/10 ; 89 Series - 8/10

4/10, 6/89 and 8/10 4-wire duct distribution cables - 88/89 series

Benefits

  • ACOME's 88 and 89 series overhead cables have been used for decades, with tens of millions of kilometres of wire installed, in fixed Telecom networks in France, Africa and the Middle East.

  • From the outset, these cables have satisfied the highest quality transmission requirements. They still provide very high speed transmission for ADSL, ADSL2+ and VDSL protocols of Internet Service Providers (ISPs).

Applications

  • The 88 and 89 series overhead network cables have been designed for urban and rural telephone distribution networks, from the sub-distributor to the connection point, all the way to the end user.
  • These 4/10, 6/10 and 8/10 cables have fibre counts of 8 to 896 pairs depending on the copper conductor cross-section.

General characteristics

Coupe descriptif partie Série 88 / 89

  1. Conductor: Red copper wire
  2. Insulation: Solid polyethylene
  3. Assembly: 4-wire stars
  4. Shielding: Tinned copper continuity wire / copolymer aluminium tape (Aluminium PE)
  5. Sheath: Black MDL polyethylene
General
Item code Range Assembly Number of pairs Diameter of the conductor Marking Colour code
L0015E 88 4-wire stars 20 p. 4/10 ACOME Std
L0016E 88 4-wire stars 14 p. 4/10 ACOME Std
L0017E 88 4-wire stars 28 p. 4/10 ACOME Std
L0018E 88 4-wire stars 56 p. 4/10 ACOME Std
L0019E 88 4-wire stars 112 p. 4/10 ACOME Std
L0020E 88 4-wire stars 224 p. 4/10 ACOME Std
L0021E 88 4-wire stars 448 p. 4/10 ACOME Std
L0022E 88 4-wire stars 896 p. 4/10 ACOME Std
L0023E 88 4-wire stars 1792 p. 4/10 ACOME Std
L0024E 88 4-wire stars 2688 p. 4/10 ACOME Std
L0025E 88 4-wire stars 20 p. 6/10 ACOME Std
L0026E 88 4-wire stars 14 p. 6/10 ACOME Std
L0027E 88 4-wire stars 28 p. 6/10 ACOME Std
L0028E 88 4-wire stars 56 p. 6/10 ACOME Std
L0029E 88 4-wire stars 112 p. 6/10 ACOME Std
L0030E 88 4-wire stars 224 p. 6/10 ACOME Std
L0031E 88 4-wire stars 448 p. 6/10 ACOME Std
L0032E 88 4-wire stars 896 p. 6/10 ACOME Std
L0033E 89 4-wire stars 20 p. 8/10 ACOME Std
L0034E 89 4-wire stars 14 p. 8/10 ACOME Std
L0035E 89 4-wire stars 28 p. 8/10 ACOME Std
L0036E 89 4-wire stars 56 p. 8/10 ACOME Std
L0037E 89 4-wire stars 112 p. 8/10 ACOME Std
L0038E 89 4-wire stars 224 p. 8/10 ACOME Std
L0039E 89 4-wire stars 448 p. 8/10 ACOME Std
Color code

Série 88 :

code couleurs série 88

Série 89 :

code couleurs série 89

 

Norms and standards

General

UTE C 93-526 & UTE C 93 - 527 -2; Compliant with the European ROHS 2002/95/EC directive

Recommendations

Storage and installation

The cables are supplied with protective wrapping that must be maintained until the product has been fully used.

You want more information ?