General characteristics
Gas tube surge protection for coaxial antenna lines. Those surge protectors have been design to protect antenna, microwaves, broadband applications, two-way radios, cellular equipment and GPS equipment against lighting surges and electrical transients. They are a first line of defense for your sensitive equipment. They employ a patented gas tube and are proposed in bulkhead version as a standard.
- 20 KA transient amps protection (8/20 µs)
- DC Pass to +/- 48 V
- Low VSWR and insertion loss
- Bi-directional
- Removable GDT
- Bulkhead
Housings: |
Brass + Cu. Zn. Sn (plating) |
Male Contacts: |
Brass + Silver (plating) |
Female: |
CuBe2 + Silver (plating) |
Waterproof Degree: |
IP65 |
Operating Temperature Range: |
- 40 ℃ to + 80 ℃ |
RoHS Compliance: |
Yes |
Test Standard: |
IEC 60529 |
Bulkhead mounting on grounding paintless plate, MH32, max.15mm for wall thickness, M8 threaded hole (MH – mounting hole, M - screw).
Connection to equipotential network by wire (2.5mm² Min. – shorter length).
Impedance: |
50 ± 1Ω |
Frequency Band: |
DC to 2500MHz |
Return Loss: |
≤-20dB(typical -23 dB) |
Insertion Loss: |
≤ 0.15 dB |
RF Power Transmission: |
1000 W (Max.) |
Breakdown Voltage: |
400~600 V (100V/s) |
Max. Discharge Current: |
20 KA (test pulse 8/20 µs) |
Residual Voltage: |
< 1000 V (1 KV/µs) |
Range
Product number |
Interface |
Bulkhead |
Weight |
C1046A |
Din male / Din male |
No |
565 g |
C0878A |
Din male / Din female |
Yes |
565 g |
C0879A |
Din female / Din female |
Yes |
550 g |