General characteristics
Inner Conductor: | Copper tube Outer Diameter: 9.25 mm |
Dielectric: | Foam Polyethylene Diameter: 22.4 mm |
Outer Conductor: | Corrugated copper Outer Diameter: 24.7 mm |
Jacket: | Black Polyethylene Diameter: 27.4 mm |
Ink marking: ACOME HYPERCELL COAX HPL 50-7/8 LA M5407 LOT X lot N° (+ Metric length)
Bending radius:
- Operating : 250 mm – Min
- Installation : 120 mm – Min
Tensile Strength: 1450 N – Max
Weight: 431 kg/km
Packaging: 500 m
Temperature range:
- Operating: -40°C / +85°C
- Installation: -25°C / +60°C
- Storage: -70°C / +85°C
Halogen content: IEC 60754-1
Test methods: IEC 60096-0-1, 61196-1, 60966-1
Impedance : 50 ± 1 Ω
Return loss :
- 400 ~ 500 MHz ≤ -26.5 dB
- 800 ~ 1000 MHz ≤ -26.5 dB
- 1700 ~ 2200 MHz ≤ -24 dB
- 2500 ~ 2700 MHz ≤ -23.5 dB
Capacitance: 73.5 pF/m
Passive Intermodulation : ≤-158 dBc
Velocity: 90%
Dielectric constant: 1.23
Screening effectiveness: > 120 dB
Operating frequency: ≤ 5 GHz
Peak power rating: 95 kW
Operating voltage: 3 kV RMS
Insulation Resistance: > 10000 MΩ.km
DC resistance:
- Inner conductor: ≤ 1.55 Ω/km
- Outer conductor: ≤ 1.40 Ω/km
Frequency (MHz) |
Attenuation (dB/100m) @ 20°C Typical |
Power kW @ 40°C-Ambient Temperature Inner conductor: 100°C |
30 |
0.59 |
16.29 |
80 |
0.98 |
9.85 |
150 |
1.37 |
7.10 |
450 |
2.45 |
3.97 |
824 |
3.42 |
2.86 |
900 |
3.56 |
2.72 |
960 |
3.73 |
2.63 |
1000 |
3.78 |
2.57 |
1500 |
4.74 |
2.04 |
1700 |
5.17 |
1.91 |
1800 |
5.25 |
1.84 |
1900 |
5.41 |
1.79 |
2000 |
5.58 |
1.70 |
2200 |
5.89 |
1.65 |
2300 |
6.04 |
1.60 |
2400 |
6.19 |
1.56 |
2500 |
6.34 |
1.53 |
3000 |
7.06 |
1.37 |
3300 |
7.46 |
1.29 |
3400 |
7.60 |
1.26 |
3500 |
7.73 |
1.25 |
3600 |
7.86 |
1.22 |
3800 |
8.12 |
1.18 |
5000 |
9.69 |
0.90 |