Product
C0600A

C0877A
HYPERCELL

HPL Quarter Wave Surge Arrestor

General characteristics

Quarter-wave surge protection for coaxial antenna lines. This technology also known as "Shorting Stub", provides an excellent protection against any surges especially against lightning surges. Thanks to their technology, they need no special maintenance and provide a very low residual voltage. To achieve very low inter-modulation, these protectors are designed with a minimum of separate parts (minimum contacts) and the raw material and surface treatment are non-magnetic. This protector is tuned for a specific frequency range and so is not able to transmit DC supply.

  • Wide band
  • Very high discharge capacity
  • Very low residual voltage
  • Maintenance free
  • Bulkhead as a standard

 

MECHANICAL

Housings:

Brass + Cu. Zn. Sn (plating)

Male Contacts:

Brass + Silver (plating)

Female Contacts:

Bronze + Silver (plating)

Insulator:

PTFE

Gaskets:

Silicone rubber

  

ENVIRONMENTAL

Waterproof Degree:

IP65

Operating Temperature Range:

- 40 ℃ to + 85 ℃

RoHS Compliance:

Yes

Test Standard:

IEC 60529

  

MOUNTING AND GROUNDING

Bulkhead mounting on grounding paintless plate, MH32, max.15mm for wall thickness, M8 threaded hole (MH – mounting hole, M - screw).

Connection to equipotential network by wire (2.5mm² Min. – shorter length).

 

ELECTRICAL

Impedance:

50 ± 1Ω

Frequency Band:

800 ~ 2200MHz

Return Loss:

≤-20dB

Insertion Loss:

≤ 0.2 dB

RF Power Transmission:

2500 W (Max.)

Intermodulation:

≤ -150 dBc

Max. Discharge Current:

100 KA (test pulse 8/20 µs)

 

Range

Product number

Interface

Bulkhead

Weight

C0600A

Din female /

Din male

Yes

669 g

C0876A

Din female /

Din male

No

492 g

C0602A

Din female /

Din female

Yes

645g

C0877A

Din female /

Din female

No

475g

  