Product
photo produit ACOME M5554Z

M5554Z
HYPERCELL

HPL 50-3/8 SF – Fire resistant LSOH Jacket

General characteristics

Inner Conductor:

Copper – clad Aluminium

2.6 mm

Dielectric:

Foam Polyethylene

  6.7 mm

Outer Conductor:

Corrugated copper

  9.1 mm

Jacket:

Low smoke Zero Halogen Compound

10.2 mm

 

Ink Marking: ACOME HYPERCELL COAX LSOH HPL 50-3/8SF SUPER FLEXIBLE M5554 LOT X lot N°(+Metric length)

 

MECHANICAL

Bending Radius:

  • Operating: 45mm-Min
  • Installation: 25mm-Min
  • Tensile Strength: 600N -Max
  • Weight: 125kg/km
  • Packaging: 500 m

 

ENVIRONMENTAL
  • Operating temperature range: -40-+85℃

 

 

 

ELECTRICAL

Impedance: 50Ω
Return Loss/:

  • 380 ~ 500 MHz ≤ -26.5 dB
  • 694 ~ 960 MHz ≤ -26.5 dB
  • 1700 ~ 2200 MHz ≤ -24 dB
  • 2500 ~ 2700 MHz ≤ -23.5 dB
  • 3400~4000Mhz ≤ -22 dB

Capacitance: 82 pF/m
Passive Intermodulation: ≤-160 dBc
Velocity: 82%
Dielectric Constant: 1.52
Screening Effectiveness: > 120 dB
Operating Frequency: ≤ 13 GHz
Peak Power Rating: 11.9 kW
Operating Voltage: 0.84 kV RMS
Insulation Resistance: > 10000 MΩ.kmDC Resistance:

  • Inner conductor ≤ 5.50 Ω/km
  • Outer conductor ≤ 5.10 Ω/km

 

Frequency

(MHz)

Attenuation

(dB/100m)

@ 20°C Typical

Power kW

@ 40°C- Ambient Temperature Inner conductor: 100°C

30

2.27

3.06

80

3.75

1.88

150

5.16

1.36

450

9.14

0.78

824

12.60

0.56

900

13.20

0.54

960

13.62

0.53

1000

13.90

0.52

1500

17.35

0.42

1700

18.60

0.39

1800

19.20

0.37

1900

19.76

0.36

2000

20.30

0.35

2200

21.40

0.33

2300

21.95

0.32

2400

22.48

0.316

2500

23.0

0.31

3000

25.47

0.28

3300

26.90

0.26

3400

27.34

0.25

3500

27.79

0.24

3600

28.24

0.23

3800

29.18

0.21

 

Range

 

 

Norms and standards

RESISTANCE AU FEU
  • IEC 60332-1 / 60332-3C
  • IEC 60754-2
  • IEC 61034

 

Recommendations

 

 

STORAGE & INSTALLATION

Température :

  • Installation : -20-+60℃
  • Stockage : -70-+85℃

 

You want more information ?

Related products